Note
You can return to the Default Auto settings at any time by pressing and holding down the
Layout key and then pressing the 0 key.
You can configure your monitor so that the user sees two or three video streams on the
monitor(s): local video, remote video, and a data presentation.
PIP (Picture In Picture) displays two overlapped images on one monitor, where the remote
image is in full-screen format, and local image is in a smaller, overlapped window.
PaP (Picture and Picture) displays two images side-by-side on one monitor, where the
remote image and the local image have the same size, emulating a dual-monitor setup.
PoP (Picture out Picture) displays two images side-by-side on one monitor, where the
remote image is larger than the local image.
Procedure
Step 1
Access the general monitor settings as follows:
From the endpoint, select Configure > Advanced > I/O connections > Monitor >
General.
From the web interface, select Administrator settings > I/O connections > Monitor >
General.
Figure 5-26 Configuring the general monitor settings from the web interface
Step 2
Configure the settings as described in Table 5-10 on page 71.